ABSTRACT
BACKGROUND: High cost of commercial RNA extraction kits limits the testing efficiency of SARS-CoV-2. Here, we developed a simple nucleic acid extraction method for the detection of SARS-CoV-2 directly from nasopharyngeal swab samples. METHODS: A pH sensitive dye was used as the end point detection method. The obvious colour changes between positive and negative reactions eliminates the need of other equipment. RESULTS: Clinical testing using 260 samples showed 92.7% sensitivity (95% CI 87.3-96.3%) and 93.6% specificity (95% CI 87.3-97.4%) of RT-LAMP. CONCLUSIONS: The simple RNA extraction method minimizes the need for any extensive laboratory set-up. We suggest combining this simple nucleic acid extraction method and RT-LAMP technology as the point-of care diagnostic tool.
Subject(s)
COVID-19 Testing , COVID-19 , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/virology , COVID-19 Testing/methods , Humans , Molecular Diagnostic Techniques/methods , Nasopharynx/virology , Nucleic Acid Amplification Techniques/methods , Point-of-Care Systems , RNA, Viral/analysis , RNA, Viral/genetics , RNA, Viral/isolation & purification , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Sensitivity and SpecificityABSTRACT
BACKGROUND: Current diagnosis of SARS-CoV-2 infection relies on RNA purification prior to amplification. Typical extraction methods limit the processing speed and turnaround time for SARS-CoV-2 diagnostic testing. METHODS: Here, we applied reverse transcription loop-mediated isothermal amplification directly onto human clinical swabs samples to amplify the RNA from SARS-CoV-2 swab samples after processing with chelating resin. RESULTS: By testing our method on 64 samples, we managed to develop an RT-LAMP assay with 95.9% sensitivity (95% CI 86 to 99.5%) and 100% specificity (95% CI 78.2-100%). CONCLUSION: The entire process including sample processing can be completed in approximately 50 min. This method has promising potential to be applied as a fast, simple and inexpensive diagnostic tool for the detection of SARS-CoV-2.
ABSTRACT
BACKGROUND: Current assays for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) rely on time consuming, costly and laboratory based methods for virus isolation, purification and removing inhibitors. To address this limitation, we propose a simple method for testing RNA from nasopharyngeal swab samples that bypasses the RNA purification step. METHODS: In the current project, we have described two extraction-free reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for the detection of SARS-CoV-2 by using E gene and RdRp gene as the targets. RESULTS: Here, results showed that reverse transcription loop-mediated isothermal amplification assays with 88.4% sensitive (95% CI: 74.9-96.1%) and 67.4% sensitive (95% CI: 51.5-80.9%) for E gene and RdRp gene, respectively. CONCLUSION: Without the need of RNA purification, our developed RT-LAMP assays for direct detection of SARS-CoV-2 from nasopharyngeal swab samples could be turned into alternatives to qRT-PCR for rapid screening.
Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA, Viral/genetics , Reverse Transcription , Sensitivity and SpecificityABSTRACT
[This corrects the article DOI: 10.1371/journal.pone.0245164.].
ABSTRACT
BACKGROUND: Asymptomatic severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infections are well documented. Healthcare workers (HCW) are at increased risk of infection due to occupational exposure to infected patients. We aim to determine the prevalence of SARS-CoV-2 antibodies among HCW who did not come to medical attention. METHODS: We prospectively recruited 400 HCW from the National Public Health Laboratory and two COVID-19 designated public hospitals in Klang Valley, Malaysia between 13/4/2020 and 12/5/2020. Quota sampling was used to ensure representativeness of HCW involved in direct and indirect patient care. All participants answered a self-administered questionnaire and blood samples were taken to test for SARS-CoV-2 antibodies by surrogate virus neutralization test. FINDINGS: The study population comprised 154 (38.5%) nurses, 103 (25.8%) medical doctors, 47 (11.8%) laboratory technologists and others (23.9%). A majority (68.9%) reported exposure to SARS-CoV-2 in the past month within their respective workplaces. Adherence to personal protection equipment (PPE) guidelines and hand hygiene were good, ranging from 91-100% compliance. None (95% CI: 0, 0.0095) of the participants had SARS-CoV-2 antibodies detected, despite 182 (45.5%) reporting some symptoms one month prior to study recruitment. One hundred and fifteen (29%) of participants claimed to have had contact with known COVID-19 persons outside of their workplace. INTERPRETATION: Zero seroprevalence among HCW suggests a low incidence of undiagnosed COVID-19 infection in our healthcare setting during the first local wave of SARS-CoV-2 infection. The occupational risk of SARS-CoV-2 transmission within healthcare facilities can be prevented by adherence to infection control measures and appropriate use of PPE.
ABSTRACT
Rapid diagnosis is an important intervention in managing the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) outbreak. Real time reverse transcription polymerase chain reaction (RT-qPCR) remains the primary means for diagnosing the new virus strain but it is time consuming and costly. Recombinase polymerase amplification (RPA) is an isothermal amplification assay that does not require a PCR machine. It is an affordable, rapid, and simple assay. In this study, we developed and optimized a sensitive reverse transcription (RT)-RPA assay for the rapid detection of SARS-CoV-2 using SYBR Green I and/or lateral flow (LF) strip. The analytical sensitivity and specificity of the RT-RPA assay were tested by using 10-fold serial diluted synthetic RNA and genomic RNA of similar viruses, respectively. Clinical sensitivity and specificity of the RT-RPA assay were carried out using 78 positive and 35 negative nasopharyngeal samples. The detection limit of both RPA and RT-qPCR assays was 7.659 and 5 copies/µL RNA, respectively with no cross reactivity with other viruses. The clinical sensitivity and specificity of RT-RPA were 98% and 100%, respectively. Our study showed that RT-RPA represents a viable alternative to RT-qPCR for the detection of SARS-CoV-2, especially in areas with limited infrastructure.
Subject(s)
COVID-19/diagnosis , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , COVID-19/genetics , Humans , Malaysia/epidemiology , Nucleic Acid Amplification Techniques/methods , Recombinases/genetics , Recombinases/metabolism , Reverse Transcription/genetics , SARS-CoV-2/pathogenicity , Sensitivity and SpecificityABSTRACT
A simple and rapid reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of SARS-CoV-2. The RT-LAMP assay was highly specific for SARS-CoV-2 and was able to detect one copy of transcribed SARS-CoV-2 RNA within 24 minutes. Assay validation performed using 50 positive and 32 negative clinical samples showed 100% sensitivity and specificity. The RT-LAMP would be valuable for clinical diagnosis and epidemiological surveillance of SARS-CoV-2 infection in resource-limited areas as it does not require the use of sophisticated and costly equipment.
Subject(s)
COVID-19 Testing/standards , COVID-19/diagnosis , COVID-19/epidemiology , Molecular Diagnostic Techniques/standards , Nucleic Acid Amplification Techniques/standards , Pandemics , RNA, Viral/genetics , SARS-CoV-2/genetics , COVID-19/mortality , COVID-19/transmission , COVID-19 Testing/methods , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , Reverse Transcription , SARS-CoV-2/pathogenicity , Sensitivity and SpecificityABSTRACT
BACKGROUND: Highly sensitive real-time reverse transcription polymerase chain reaction (RT-qPCR) methods have been developed for the detection of SARS-CoV-2. However, they are costly. Loop-mediated isothermal amplification (LAMP) assay has emerged as a novel alternative isothermal amplification method for the detection of nucleic acid. METHODS: A rapid, sensitive and specific real-time reverse transcription LAMP (RT-LAMP) assay was developed for SARS-CoV-2 detection. RESULTS: This assay detected one copy/reaction of SARS-CoV-2 RNA in 30 min. Both the clinical sensitivity and specificity of this assay were 100%. The RT-LAMP showed comparable performance with RT-qPCR. Combining simplicity and cost-effectiveness, this assay is therefore recommended for use in resource resource-limited settings.